Accumulator manufacturer of battery products installation precautions

The product of energy storage device should be located in a place convenient for inspection and maintenance.In case of shock absorption and pulsation, the energy storage device should be set in a place close to the vibration source and prone to impact, set away from the heat source and prevent the system pressure from rising due to the thermal expansion of the gas.The accumulator should be firmly fixed, but not allowed to be welded on the body. It should be firmly supported on the sliding frame or wall surface.In the case that the diameter is too long, it is necessary to set kappos for reinforcement.

In principle, the burst-type accumulator should be installed with the oil port vertically. During the installation of the burst-type accumulator, the burst-type accumulator should be in contact with one side of the shell due to buoyancy, which hinders the normal telescopic operation. Zhenhai burst-type accumulator company has accelerated the damage of the burst-type accumulator, and there is a risk of reducing the function of circuit breaker.Therefore, inclined or horizontal installation is generally not used.

There are no special installation requirements for diaphragm accumulators. The oil port can be installed vertically, and the installation can be inclined or horizontal.A one-way valve shall be installed between the pump and the accumulator. When the pump stops, the oil in the evaporator shall flow back to the tank inside the pump to avoid accidents.An energy saver is a device for storing oil pressure energy in a hydraulic system.Its main function is to assist the power source, eliminate the leakage and pressure pulsation, absorb the pressure impact of ningbo capsule accumulator company.

In the work cycle of the hydraulic system in different stages of the required flow changes a large, always use energy storage and a small flow of the pump constitute the oil source.When the system needs a smaller flow, the concentrator can store the additional flow of the hydraulic pump and stop the pump work at the same time.When the system needs a short time, the accumulator releases the stored hydraulic fluid and supplies oil to the system with the pump.The hydraulic system needs a long time to maintain the pressure. Beilun capsule accumulator company needs to unload the hydraulic pump. At this time, the accumulator is used to discharge the stored hydraulic fluid and compensate the leakage of the system to maintain the pressure of the system.The energy storage device can be set at the outlet of the pump to absorb the pressure pulsation of the pump and improve the stability of the system.

When a sudden closing of the hydraulic valve or a change of direction may result in a pressure shock to the system, install the bracket at the pressure shock and install its absorption function to reduce the peak pressure shock.