Bladder accumulator

Tel:0574-88850487 | 中文 / EN

Website:en.haofayy.com

Accumulator manufacturer
your current location : Home >> Product display >> Accumulator
National standard accumulator

National standard accumulator

  • category:Accumulator
  • Views:Times
  • Release date:2019-11-21
  • Technical Parameters
  • product description

1.jpg

2.jpg

Installation location:

Pneumatic capsule accumulator wholesale can be installed vertically, horizontally and tilting.Select the inclined and vertical mounting position and place the oil valve below.

Please use the following accumulator installation location first:

1. Fixed mode:

The accumulator capacity is less than 1 liter and can be directly installed on the pipeline.In the case of strong vibration and a capacity of more than 1 liter, it is recommended to use the clamp or a whole set of accumulator fixed components manufactured by our company

2. Nitrogen installation:

To make the accumulator work, nitrogen must be filled into the capsule.Nitrogen charging is carried out with charging (nitrogen) tools. It is recommended to use CQ charging tools manufactured by the company. If the pressure of nitrogen cannot meet the requirements of (high pressure) accumulator, it is suggested to use nitrogen charging device -CDZ nitrogen charging car manufactured by the company

3. Matters needing attention:

No welding or any mechanical processing shall be carried out on the accumulator shell;The capsule of the accumulator should only be filled with nitrogen. Oxygen and other inflammable and corrosive gases should not be used.The accumulator shall be installed in the hydraulic system supplied by the relief valve or other safety valve.