The safe use and maintenance of accumulators mainly include the assembly and maintenance of accumulators, fault detection and elimination, and repairs. Accumulator assembly includes pre-assembly inspection, assembly, and nitrogen charging. Accumulator wholesale, click for details! Proper assembly, adjustment, and gas charging are key prerequisites for the normal operation of the accumulator and the exertion of its corresponding functions. The measurement of parameters and the correct and safe use of various tools and instruments cannot be ignored.Accumulator price please contact us if you need to know!

 

Do you know the use and maintenance of accumulators?


Key points for the safe use and maintenance of accumulators

1. Accumulators should be installed in a location that is easy to inspect and maintain, and away from heat sources.

2. Relevant safety regulations for pressure vessels must be implemented, and their maintenance must be carried out by professional maintenance companies.

3. Do not disassemble an accumulator when it is under oil pressure.

4. Gas-charged accumulators must be strictly prohibited from being charged with oxygen and should be charged with inert gas.

During the entire process of safe use, the gas charging pressure of the accumulator must be checked regularly. Non-isolated accumulators and bladder-type accumulators should be installed vertically with the valve facing upwards. We are a professional accumulator manufacturer, you can trust us! After long-term shutdown, the shut-off valve between the accumulator and the system pipeline should be closed to maintain the accumulator oil pressure above the gas charging pressure. A shut-off valve should be installed between the accumulator and the pipeline system for use during gas charging and maintenance. During normal safe use, the internal corrosion and coating peeling of the accumulator should be checked regularly as required. Accumulators that absorb shock pressure and pulsating pressure should be installed as close to the vibration source as possible.